Info: | |
Data type: |
Description:
Runtime error when cam automats are active during the calculation of a compensation gear. The 'effective' master compensation is below the minimum value (AUT_COMP_MA_S_MIN). See also error number 5101. Only registered once following a start or restart.
Reaction:
The compensation is calculated with the limit value.
As a result, the master interval is shifted.
Cause/Remedy:
Event with the ncAT_ONCE attribute occurs mistakenly.
Master compensation path is too short.
Master curve period is too large.
Master multiplication factors are too large.